COMPANY PROFILE | E-MAIL | KOREAN    
 
   
 

 HC2 Relay

 1. Flat type: 16mm *22.2 *10.9(height)
 2. High sensitivity: 200mW(1 From A)
 3. High capacity type(16A) available
 4. Ideal for switching power supplies
     on small size

1. Contact Data

Contact  Form

1A(SPST)

1C(SPDT), 1A(SPST)

Contact  Ratings

1AT(16A)-type

1A(10A), 1C(10A)-type

16A 125VAC
10A  30VDC
8A 250VAC

 10A 125VAC
5A 30VDC
5A 250VAC

Contact  Material

Silver Alloy

Contact Resistance

50m¥Ø Max

at 24VDC 1A

Max. switching voltage

250VAC / 30VDC

Max. switching current

16A

10A

Max. switching power

2000VA, 300W

1,250VA, 150W

Life Expectancy

Electrical

100,000 Operations

Machanical

10,000,000 Operations

2. General Data

Insulation Resistance

100M¥Ø, Min at 500VDC

Dielectric Strength
Between

Open Contacts

1,000VAC (for one minute)

Contacts and coil

1,500VAC (for one minute)

Operate Time

10ms

Release Time

4ms

Temperature Range

-40 to +70¡É

Shock Resistance

Malfunction

100m/s2

Mechanical

1,000m/s2

Vibration Resistance

10-55Hz, 1.5mm

Humidity

35% ~ 85%RH

Termination

PCB Coil terminal

Power consumption

1A : 200mW, 1C : 400mW

Weight

Approx. 8g

Safety Standard (UL)

UL E222977

3. Coil Data

Nominal
Voltage
VDC

Pick-up
Voltage
VDC

Drop-out
Voltage
VDC

Nominal current
mA (+/-10%)

Coil Resistance
Tolerance: ± 10% (ohm)

   1A Type

 1C Type

 1C Type

   1A Type

5

4.0

0.25

40

80

62.5

125

6

4.8

0.3

33.3

66.7

90

180

9

7.2

0.45

22.2

44.4

202.5

405

12

9.6

0.6

16.7

33.3

360

720

18

14.4

0.9

11.1

22.2

810

1,620

24

19.2

1.2

8.3

16.7

1,440

2,880

48

38.4

2.4

4.2

8.3

5,760

11,520

100

80

5

6

6

16,600

16,600

4. Ordering Code

5. Overall And Mounting Dimensions