COMPANY PROFILE | E-MAIL | KOREAN    
 
   
   
 

 

 1 Form A configurations
 Extremely small footprint utilizing PCB area
 Highly efficient magnetic circuit for 0.2W

HU Relay

  

1. Contact Data

Contact  Form

1 Form A

Contact  Material

Silver Alloy

Contact  Ratings

3A at 277VAC, 3A at 30VDC

Max Switching Voltage

277VAC, 30VDC

Max Switching Current

3A

Max Switching Power

831VA, 90W

Contact Resistance

 100m ohm at 6VDC 1A

Life Expectancy Electrical

200,000 operations ( at 3A 125VAC, 3A 30VDC)
 100,000 operations ( at 3A 250VAC)

Machanical

5,000,000 operations

2. General Data

Insulation Resistance

1,000M Min  at  500VDC

Dielectric Strength Between

Open Contacts

750VAC (for one minute)

Contacts and coil

4,000VAC (for one minute)

Surge Voltage between Contacts
and coil

10kv (1.2 x 50 micro S)

Operate Time

10ms

Release Time

10ms

Temperature Range

-40 to+70 C

Temperature rice

 Max. 45 C with normal coil voltage and 3A contact
carrying current

Shock Resistance

Operating Extremes

10G

Damage Limits

100G

Vibration Resistance

10-55Hz, 1.5mm

Humidity

35-85%

Weight

Approx  4g

Safety Standard

UL E197546

3. Coil Data

Nominal
Voltage
(VDC)

Pick-up
Voltage
VDC

Drop-out
Voltage
VDC

Max allowable
Voltage
at 20 C

Coil Resistance at 20±10%(¥Ø)

 4.5

3.38

0.23

4.95

101

5

3.75

0.25

5.5

125

6

4.5

0.3

6.6

180

9

6.75

0.45

9.9

405

12

9

0.6

13.2

720

18

13.5

0.9

19.8

1,620

24

18

1.2

26.4

2,880

4. Ordering Code

HU-12

 HU

Model Name

 12

Coil voltages (4.5, 5, 6, 9, 12, 18, 24)

 

5. Overall And Mounting Dimensions