COMPANY PROFILE | E-MAIL | KOREAN    
 
   
 
 

 * 1 Form A, 2 Form A

 * 5A, 10A Contact ratings
    in compact Package,  
    sealed types

 HL3 Relay

  

1. Contact Data

Contact  Form

1A (10A)

 2A (5A)

Contact  Material

AgsnO

Contact  Ratings

10A 250VAC/30VDC

5A 250VAC/30VDC

Max Switching Voltage

250VAC/30VDC

Max Switching Current

12A

7A

Max Switching Power

2,500VA/300W

1,250VA/150W

Contact Resistance

 100m ohm at 6VDC 1A

Life Expectancy Electrical

100,000 operations ( at 30 operations / minute)

Machanical

10,000,000 operations

2. General Data

Insulation Resistance

100M Min  at  500VDC

Dielectric Strength Between

Open Contacts

1,000VAC (for one minute)

Contacts and coil

4,000VAC (for one minute)

Operate Time

20ms

Release Time

10ms

Temperature Range

-40 to+70 C

Shock Resistance

Operating Extremes

10G

Damage Limits

100G

Vibration Resistance

10-55Hz, 1.5mm

Humidity

20-85%

Weight

Appro x 11g

Safety Standard

UL E197546

3. Coil Data

Nominal
Voltage
(VDC)

Coil Resistance at 20±10%(ohm)

Max Operate
Voltage
VDC

Min Release
Voltage
VDC

Max Applicable
Voltage
VDC

0.25W

0.54W

 3

36

16.7

2.25

0.3

3.9

5

100

46.3

3.75

0.5

6.5

6

144

66.7

4.5

0.6

7.8

9

324

150

6.75

0.9

11.7

12

576

266.7

9

1.2

15.6

24

2,304

1,066.7

18

2.4

31.2

48

9,126±15%

4,266.7±15%

36

4.8

62.4

4. Ordering Code