HM4
Relay |
|
|
20A Switching capabilities SPST-No configurations Withstand inrush
current of 60 A |
1. Contact Data
|
Contact Form |
1A(SPST) |
|
Contact Material
|
Silver Alloy |
|
Contact Ratings |
20A 250VAC |
|
Contact
Resistance |
50m¥Ø
Max at 6 VDC 1A |
|
Max. switching voltage |
Max. 250VAC |
|
Max. switching current |
Max. 25A |
|
Max. switching power |
6,250VA/450W |
|
Life Expectancy Electrical
|
100,000
Operations |
|
Machanical |
5,000,000
Operations |
2. General Data
|
Insulation
Resistance |
1000M¥Ø, Min at
500VDC |
|
Dielectric Strength
Between |
Open Contacts
|
1,000VAC
(for one minute) |
|
Contacts and coil
|
2,000VAC
(for one minute) |
Surge Voltage
between Contacts and coil |
10000V (at 1.2X50us) |
|
Operate Time
|
15ms |
|
Release Time
|
10ms |
|
Temperature
Range
|
-25 to +55¡É |
|
Shock
Resistance |
Malfunction |
200m/s2 |
|
Mechanical |
1,000m/s2 |
|
Vibration
Resistance |
10-55Hz,
1.5mm |
|
Humidity |
35% ~
95%RH |
| Termination |
|
|
Weight |
Approx. .
42g |
|
Safety Standard (UL) |
UL E222977 |
3. Coil Data
|
Nominal Voltage VDC |
Pick-up Voltage VDC |
Drop-out Voltage VDC |
Max. allowable Voltage
VDC ( at 20 ° C ) |
Coil Resistance Tolerance:
± 10% ohm |
|
5 |
3.5 |
0.5 |
5.5 |
27.8 |
|
6 |
4. 2 |
0.6 |
6.6 |
40 |
|
12 |
8.4 |
1.2 |
13.2 |
160 |
|
24 |
16.8 |
2.4 |
26.4 |
640 |
|
48 |
33.6 |
4.8 |
52.8 |
2,560 |
4.
Ordering Code

5. Overall And Mounting Dimensions
6. Useful Curves

|